No items found.

Purification kits

Nucleic acid extraction that's so streamlined, it's sample prep you'll look forward to.

Pre-aliquoted reagents mean less pipetting, and half the hands-on time of other automated extractors. Just mix, load, and press Start. The microfluidic cartridge safely stores the waste. Retrieve your nucleic acids in a standard tube strip.

Find the kit that's right for your application. Available to purchase online, for Redbud NA1 owners only.

width
height
length
$ 699.00 USD

The details

Gold-standard extraction, meet microfluidic automation.

Redbud NA1 Purification kits use microfluidic cartridges to automate magnetic bead workflows, enabling a streamlined experience that will change how you think about nucleic acid extraction.

Goes anywhere. With a flexible workflow and room temperature storage, Redbud NA1 Purification kits can move to meet your workflows. Run automated extractions inside a biosafety cabinet, on the benchtop, or wherever your laboratory needs it.

Anyone can use it. Take advantage of our training videos and user-developed protocols. Within 15 minutes, your team can self-train to run extractions with confidence. Make your molecular workflows more consistent and your workforce more resilient.

Shortest hands-on time. Mix your sample with the pre-aliquoted buffers, load the mixture onto the microfluidic cartridge, and insert it into the instrument. There's nothing more to do: just press Start. Extractions on Redbud NA1 take half the hands-on time of other automated extractors.

Gold standard chemistry. Redbud NA1 automates magnetic bead workflows in a microfluidic cartridge. It's a streamlined version of the same gold-standard chemistries you already trust to prepare your nucleic acids for PCR or sequencing.

No maintenance. No reagent bottles or pipette tips to replace. Waste stays in the sealed microfluidic cartridge for biosafe disposal. With no sample- or reagent-contacting parts in the instrument, you can just wipe it down and walk away.

Included in kit

6 single-use microfluidic cartridges
Pre-aliquoted reagent box

Extractions per kit

48

Extractions per microfluidic cartridge

8

Sample volumes

200 μL input
50 µL output

Runtime

40 minutes

Storage conditions

Room temperature (15º–30ºC)

Shelf life

6 months

Regulatory status

Research use only

Cartridges per kit

6

Pre-loaded on-cartridge reagents

On-cartridge (sealed), pre-aliquoted (tubes)

Current applications

Magnetic beads, wash buffer, elution buffer

Included kit reagents

Proteinase K, pre-aliquoted lysis and binding buffer

Requires separately

Vortex mixer, P1000 pipette, P10 pipette, centrifuge

Principle of operation

Microfluidic magnetic bead-based extraction

Compatible downstream

qPCR, next-gen sequencing

Applications

Rabies, viral surveillance

Concordance with gold standard methods

High vs. existing workflows (public health lab evaluations)

Purchase options

Credit card (p-card), purchase order, third-party distributors

Returns

No-fault return policy

Training

Included — minutes to complete

Support

Email support@redbudlabs.com, self-service redbudlabs.com/support

The details

Sample prep you will look forward to.

Redbud NA1 is built on microfluidics, not bulky and finicky robots, enabling a streamlined experience that will change how you think about nucleic acid extraction.

Goes anywhere. Weighing under 24 pounds (11 kg), Redbud NA1 can move to meet your workflows. It even has a built-in handle. Run automated extractions inside a biosafety cabinet, on the benchtop, or wherever your laboratory needs it.

Anyone can use it. Plug it in, turn it on, and you're ready to run. With Redbud NA1, your team can self-train to run extractions in under 15 minutes. Make your molecular workflows more consistent and your workforce more resilient.

Shortest hands-on time. With no reagents to aliquot, nothing on the instrument to set up, and no software menus to navigate, extractions on Redbud NA1 take half the hands-on time of other automated extractors. Just load the cartridge and press Start.

Gold-standard chemistry. Redbud NA1 automates magnetic bead workflows in a microfluidic cartridge. It's a streamlined version of the same gold-standard chemistries you already trust to prepare your nucleic acids for PCR or sequencing.

No maintenance. No sample- or reagent-contacting components. No pipetters. No gantries or o-rings. Microfluidic technologies make Redbud NA1 simpler and more reliable than any other automation platform. A 2 year warranty is included, with options to extend.

Dimensions

11.5 × 14 × 15 inches (29 x 36 x 38 cm)

Weight

24 lbs (11 kg)

Power Input

90 to 264 V AC, 47 to 63 Hz

Throughput

8 samples per run

Run time

40 minutes

FAQs

What applications are supported?

Redbud NA1 Purification kits are optimized for extracting pathogenic RNA and DNA. Learn how our customers are using Redbud NA1.

What input samples are supported?

Redbud NA1 is being used with a wide range of input biospecimens, including swabs, sputum, stool, tissue, and blood. Learn how our customers are using Redbud NA1.